P2AF3
Starter Relay C Control Circuit Low
P2AF3 sets when the control line of starter relay C is pulled toward ground at a moment the module expects a different level. What that does to the relay depends on the driver type: with ground-side switching the short acts like a permanent on command, with supply-side switching the coil never gets current. No manufacturer publishes a set condition for P2AF3. Stellantis uses relay C as Starter Relay 3, the battery isolation relay of its stop-start Jeep and RAM models, where an energised coil splits the two batteries; only the stuck codes of that relay appear in its bulletins. GM's comparable short-to-ground test on the tandem starter pinion relay (P26E5) looks for 0.5 Ω or less to ground with 8 failures in 10 samples, Type B. Open and short-to-voltage faults are P2AF2 and P2AF4.
Possible causes
- Control wire chafed through to ground high
- Shorted relay coil medium
- Faulty output driver in the control module low
Symptoms
- Stop-start inoperative
- Relay energised all the time or not at all, depending on circuit design
- Possible no-crank
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P2AF3
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.