P2AE8
Intake Air O2 Sensor Negative Current Control Circuit High Bank 1
P2AE8 reports that, on bank 1's intake air oxygen sensor, the negative current control line sits above its intended level. For the bias on this return to climb towards battery voltage, something must feed it: most often the heater supply sharing the six-pin plug, sometimes condensate in a connector that collects moisture from the intake air. With the reference raised, the ECM loses its anchor for regulating the Nernst cell and discards the oxygen value. Ford handles a VM lead shorted to battery on exhaust probes under P0132, and the Bosch LSU 4.9 sheet lists the trim, pump and return pins side by side, which shows how close these faults sit. No manufacturer documents P2AE8 publicly. P2AE6 is the open fault, P2AE7 the low one, P2AE5 the high fault on the pump lead, P2AF1 bank 2.
Possible causes
- Return lead shorted to the heater supply high
- Condensate inside the sensor connector medium
- Internal short between heater and cell low
Symptoms
- Check engine light on
- EGR reduced, NOx may rise
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P2AE8
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?