P2AE3
Intake Air O2 Sensor Pumping Current Circuit Open Bank 1
P2AE3 reports a break in the pumping current lead of the bank 1 intake oxygen sensor, pin 1 of a Bosch LSU 4.9 (APE/IP). Through this wire the ECM drives current into the pump cell while the Nernst cell is kept on its set point; Ford's patent US9441564B2 explains that the size of that current reflects the oxygen share of the charge, from which the EGR dilution is calculated. With the lead open, no current flows and the reading freezes. For the exhaust twin P2237 Ford detects this when reference-current pulses shift lambda by 0.05 or less within 20 s. In the intake, where the gas always stays lean, such a test would have to rely on EGR changes instead; no manufacturer publishes P2AE3 to confirm how. P2AE4/P2AE5 are low/high, P2AE6 the open return, P2AEC bank 2.
Possible causes
- Pump current lead (pin 1) broken high
- Sensor plug loose or not latched medium
- Pump cell inside the sensor open low
Symptoms
- Check engine light on
- EGR runs without sensor feedback or is switched off
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P2AE3
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.