P2AC2
Intake Air O2 Sensor Reference Voltage Circuit High Bank 1
P2AC2 means the reference voltage at the intake oxygen sensor of bank 1 reads above its permitted range. A reference lead shorted to a supply wire or battery voltage in the harness, a lost ground on the sensor side or water in the connector are the usual triggers; a sensor with an internally damaged cell can produce the same picture. The intake sensor sits in a damp, oil-misted environment near the crankcase ventilation and EGR inlet, so connector corrosion deserves a look. No manufacturer publishes P2AC2 with thresholds; CARB's rule for comprehensive input components and Ford's patents on the sensor itself are the basis here. As with the other faults in this family, the ECM loses its measurement of recirculated exhaust and falls back to model-based or reduced EGR, which can raise NOx. P2AC1 is the low counterpart, P2AC6 bank 2.
Possible causes
- Reference wire shorted to a supply or battery voltage wire high
- Moisture or corrosion bridging pins in the sensor connector medium
- Open ground on the sensor side medium
Symptoms
- Check engine light on
- EGR reduced, NOx emissions may rise
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P2AC2
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.