P2A9B
Alternative Fuel Tank Select Valve C Control Circuit Low
P2A9B is logged when the control circuit of tank select valve C reads below the expected level. Common electrical findings are a lead grounded against the frame, a pinched wire under a tank strap or a coil with internal shorts. What follows depends on how the output is wired: a ground-side driver may now keep valve C switched permanently, while a supply-side driver shuts down and lets the valve drop back. Either way the selection of the third vessel no longer follows the commands. Westport's two-vessel patent ties tank changes to empty-tank detection; with the valve out of control, that change may be skipped or forced. No manufacturer documents P2A9B or its voltage limits. Check the circuit with the valve unplugged first, then with the coil reconnected.
Possible causes
- Lead of valve C grounded against the frame or pinched under a tank strap high
- Internal short in the coil of valve C medium
- Water in the plug of valve C low
Symptoms
- Malfunction lamp on
- Third tank used constantly or not at all
- Unexpected tank changes during the drive
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P2A9B
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.