Alternative Fuel Pump A Compression Stroke Valve Control Circuit High
P2A82 shows the drive line to pump A's compression stroke valve at a higher level than the commanded state permits, most likely because the coil winding or its wire is broken where the valve is switched to ground, or because the line touches battery voltage and the output stage loses control of it. The solenoid then cannot move the spool into the fill position, so oil never reaches the drive side and pump A performs no compression stroke at all. Gas pressure downstream of the pump sinks faster than the controller expects, and on a single-element system the engine soon runs short of fuel. Caterpillar's patents show the spool going back to drain when the solenoid is de-energized, which is the state this fault produces. No manufacturer publishes P2A82. Measure coil resistance and feed voltage.
Possible causes
- Open coil or broken wire at valve A high
- Control wire shorted to battery voltage medium
- Corroded valve connector low
Symptoms
- Warning lamp on
- Falling gas pressure and power loss
- Engine may stall on gas with a single pump element
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P2A82
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?