P2A7B
Alternative Fuel Hydraulic Pressure Sensor Range/Performance
P2A7B covers a hydraulic pressure signal that is electrically valid but does not fit the operating state. Plausibility can be judged because pressures in the hydraulic drive of an LNG pump follow a known pattern: during a stroke the working side carries load pressure, while the return side stays close to reservoir level until the valve reverses. Westport's patent adds that pressure depends on hydraulic pump speed and on the LNG pressure the pump works against, so the expected values are corrected by table. A value frozen during strokes, a return pressure that climbs along with the supply, or a mismatch with the P2A75 sensor suggests drift, a blocked sensor port or a restricted return line. No manufacturer publishes limits for P2A7B.
Possible causes
- Sensor drift or offset high
- Sensor port blocked by contaminated oil medium
- Restricted return line or filter raising return pressure low
Symptoms
- Warning lamp after several drive cycles
- Irregular pump strokes or reduced power on gas
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2A7B
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 4 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.