P2A72
Alternative Fuel Hydraulic Fuel Pump Select Valve Control Circuit Low
P2A72 is set when the control circuit of the hydraulic fuel pump select valve reads lower than expected for the commanded state. On a low-side driver this typically means the control wire is shorted to ground, so the valve coil may stay energised; on a high-side driver a short to ground or a shorted coil pulls the output down and may trip its protection. Either way the controller can no longer trust which LNG tank pump is being driven. Westport's patented system relies on knowing the valve position to assign hydraulic pressure readings to the right pump, so tank selection and empty-tank detection become unreliable. No manufacturer documents P2A72. Measure coil resistance and check the harness for chafing against the chassis.
Possible causes
- Control wire chafed on the frame and shorted to ground high
- Select valve coil with shorted turns medium
- Water in the connector bridging to ground low
Symptoms
- Check engine light on
- Select valve stays switched, one tank pump runs permanently
- Gas supply interrupted when the active tank runs empty
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P2A72
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.