Alternative Fuel Hydraulic Fuel Pump Select Valve Control Range/Performance
P2A71 concerns the function of the hydraulic fuel pump select valve rather than its wiring: the circuit is intact, but the system does not respond as expected after a switch command. In Westport's design the controller links the hydraulic pressure it measures to whichever pump the selector valve should be feeding; if the pressure pattern does not match the commanded pump, or the empty-tank logic sees no change after switching, the valve is probably sticking or leaking internally. Contaminated hydraulic oil, a worn spool or a weak solenoid are typical. Caterpillar's patent describes a related directional valve whose actuator is shifted once pressure sensors detect the stroke end. No manufacturer publishes P2A71 or its limits.
Possible causes
- Valve spool sticking due to contaminated hydraulic oil high
- Worn valve leaking internally, flow reaches both pumps medium
- Solenoid force too low, for example from low supply voltage low
Symptoms
- Check engine light on
- Tank changeover does not happen or happens late
- Uneven LNG levels between tanks
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P2A71
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 4 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?