P2A62
Alternative Fuel Tank B Level Sensor Circuit High
P2A62 is set when the tank B level signal climbs above the highest voltage a working sender delivers at full. For its dual-tank propane trucks Roush blames the high case on a disconnected sender or a wire shorted to more than 5 V, and with the second-tank code P2068 the gauge again falls back to the primary tank only. A broken ground at the sender gives the same picture on most pull-up inputs. The risk is the opposite of P2A61: if the reading were accepted, tank B would look full while it empties, so the module discards it. No manufacturer documents P2A62 itself. Check that the plug at the tank B sender is seated and locked, then test ground continuity before replacing the sender.
Possible causes
- Tank B sender unplugged or wire open high
- Sender ground interrupted medium
- Signal wire shorted to a voltage above 5 V low
Symptoms
- Check engine light
- Gauge shows only the primary tank
- Content of tank B unknown to the driver
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P2A62
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.