P2A56
Alternative Fuel Vaporizer B Outlet Temperature Sensor Range/Performance
With two vaporizers fed by the same coolant, their outlet temperatures should behave alike, which gives the module a natural cross-check. P2A56 means the vaporizer B reading is electrically fine but out of line with that expectation, with the engine state or with its own history. The plausible window is wide: Westport's LNG patent gives vaporized fuel temperatures anywhere from about −20 °C to +80 °C depending on how the engine runs, so tests rely on comparisons rather than fixed values. Two causes look alike here: a drifting sensor, or vaporizer B really running colder because an air lock or kinked hose starves it of coolant. Feeling both coolant hoses settles it. The second case belongs to P2A8C. No manufacturer publishes P2A56 thresholds.
Possible causes
- Vaporizer B sensor reads off or sluggishly high
- Vaporizer B gets too little coolant (air lock, kinked or blocked hose) medium
- Sensor seated loosely in its port low
Symptoms
- Check engine light, depending on calibration
- Power drop under high load on gas
- Clear temperature gap between vaporizer A and B in live data
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P2A56
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.