P2A42
Alternative Fuel Tank B Pressure Sensor Range/Performance
Unlike its electrical siblings, P2A42 deals with a tank B pressure reading that is electrically valid but makes no sense. Examples: the value does not fall while gas is drawn from tank B, it stays frozen after refuelling, or it differs clearly from the pressure of the other cylinders after a long stop, when all tanks connected to one fill line should settle at about the same level. New Flyer's bulletin SMB-169 for CNG buses gives a sense of the scale: after filling, the high-pressure gauge is expected to show between 200 and 3,600 psi. A tank valve stuck closed (P2A23) or a closed hand valve also starves the reading of change. No manufacturer publishes P2A42 or its limits; CARB requires a rationality check for such inputs. Diagnosis compares the sensor with a mechanical gauge.
Possible causes
- Tank B pressure sensor drifting or stuck high
- Tank B solenoid stuck closed or manual valve shut medium
- Contact resistance in the sensor connector shifting the signal medium
Symptoms
- Check engine light
- Gas gauge implausible after refuelling or driving
- Reduced range on gas
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P2A42
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.