P2A3A
O2 Sensor Positive Current Control Circuit High Bank 1 Sensor 3
P2A3A means the voltage on the pump-current (positive control) lead of probe number three, bank 1, sits above its expected level. The usual culprit is contact with a supply: the heater feed runs in the same harness and connector, and moisture or heat damage at the plug can bridge the two. An offset pump current would falsify the lambda value, so the controller stops trusting it. P2A3A is not described by any manufacturer in public sources; Ford handles a short to battery on its front IP wires under P0132 instead. P2A38 is the open-circuit fault, P2A39 the low one, P2A3D the high fault on the return. The engine normally runs as before, but the lamp comes on and diagnosis starts with voltage checks at the connector.
Possible causes
- Pump-current wire touching the heater feed in harness or plug high
- Water or corrosion in the sensor connector under the car medium
- Internal short between heater and pump cell of the probe low
Symptoms
- Check engine light after repeated detection
- Sensor 3 reports an implausibly lean value
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P2A3A
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.