P2A27
Alternative Fuel Tank Shutoff Valve C Control Circuit Performance/Stuck Off
P2A27 points to valve C: electrically commanded, yet apparently still shut. With several cylinders on one manifold, a single tank that stays isolated rarely stops the engine; the others keep supplying gas, and the fault appears as shorter range or a cylinder that never empties. Ford's 2003 bi-fuel CNG system regulates to about 724 kPa and closes its tank valve below 517 kPa, which shows how gas pressure serves as the yardstick for such checks. No manufacturer publishes P2A27 or how it is tested. Contamination, a sticking armature, too little coil voltage and a closed hand valve on that cylinder are the obvious suspects. Its electrical sister codes are P2A26, P2A28 and P2A29; P2A47 rates the tank C pressure sensor.
Possible causes
- Sticking or contaminated armature in valve C medium
- Hand valve on cylinder C closed medium
- Coil voltage too low because of a poor feed or ground low
Symptoms
- Check engine light
- Cylinder C never empties
- Shorter range on gas
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P2A27
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.