P2A07
O2 Sensor Negative Voltage Bank 1 Sensor 2
Sensor 2 on bank 1 is the switching oxygen sensor behind the converter; P2A07 says its output has dropped below zero volts. Because the voltage comes from the oxygen difference across the zirconia element, a negative value points to reversed signal and return wires, a contaminated reference air path or a cracked element. No manufacturer documents P2A07 publicly. The closest documented test is Ford's: from 2011 a rear sensor held below −0.2 V for 10 s, put down to swapped wires or sensor degradation – Ford, however, files it as P2A01. A Denso patent watches for a negative output in overrun shut-off, a phase in which the exhaust behind the converter is almost pure air, to find element cracks. As long as the signal is negative, the converter cannot be assessed and the downstream trim switches off.
Possible causes
- Signal and return wires swapped, e.g. after fitting a universal sensor high
- Cracked sensing element medium
- Sensor degraded or reference air contaminated medium
Symptoms
- Check engine light on
- Catalyst monitor of bank 1 not ready
- Usually no noticeable change while driving
Inspection / repair
- Difficulty: easy
- DIY: possible
What Pro shows you for P2A07
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.