P288E
Shift Fork A Actuator Control Circuit Driver Current/Temperature Too High
P288E is a self-protection code of the output stage that powers the actuator of shift fork A. The driver reports a current above its limit or an excessive chip temperature, and the module throttles or switches off that actuator. No manufacturer documents P288E publicly. Ford's DPS6 shows where such a stage sits: a motor driver chip inside the TCM, which Ford calls the ATIC, sets the current of the three-phase motor for drum A, yet Ford books faults of that chip as P2831, not P288E. Plausible triggers are a shorted winding or lead, a drum or fork that binds so the motor stalls at full current, repeated shift attempts against a blockage, and heat in the transmission housing. CARB 13 CCR 1968.2 sets the monitoring duty. With fork A out of action, 1st, 3rd and 5th may no longer engage.
Possible causes
- Shorted winding or lead in the fork A actuator circuit high
- Binding drum or fork stalling the actuator under full current medium
- High transmission temperature adding heat to the driver low
- Defective driver stage in the control unit low
Symptoms
- Odd gears do not engage, car may start in 2nd
- Transmission warning and limp mode
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P288E
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.