P2862
Shift Fork B Actuator Circuit High
P2862 indicates that a fork B actuator line sits at or near battery voltage when it should be pulled low. In practice this is a short to a powered conductor or a module transistor that stays open. Ford documents P2862 in its 2012 OBD summary as the short-to-power check of the DPS6 motor that turns the drum for reverse and gears 2, 4 and 6; the 2014 catalogue lists the MIL for it. Ford handles the open circuit as P285F and the ground short as P2861. Because the module cannot regulate the motor phases safely, it stops the motor and leaves that drum where it is; depending on where it stops, the box may be stuck without reverse or in one even gear. Inspect the harness routing near hot or moving parts before condemning the module.
Possible causes
- Fork B actuator wire shorted to a powered conductor high
- Module output transistor for fork B stuck medium
- Insulation melted near the exhaust or a hot component low
Symptoms
- Engine lamp, no reverse or stuck in one even gear
- Large rpm jumps because only odd gears are used
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P2862
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)