P2861
Shift Fork B Actuator Circuit Low
P2861 is set when a fork B actuator line reads near ground although the module has not switched it there, the classic signature of a short to ground. Ford's 2012 DPS6 summary assigns exactly this case on the motor of the drum for reverse and the even gears to P2861, and the 2014 Ford catalogue marks it as a MIL fault. Look for a motor phase rubbed through on a bracket, corrosion bridging a terminal to the shield, or a winding that has contacted the motor housing. The other circuit faults on this motor are kept apart: P285F for an open lead, P2862 for a short to battery voltage, P2836 for the driver chip. Once the output is disabled, the car typically drives on in gears 1, 3 and 5 only, without reverse.
Possible causes
- Fork B motor lead rubbed through on a bracket or the case high
- Corrosion bridging a terminal to ground in the connector medium
- Fork B motor winding shorted to its housing medium
Symptoms
- Reverse not selectable
- Engine lamp on, only odd gears in use
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P2861
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.