P2791
Gate Select Direction Circuit Low
P2791 is set when the gate select direction signal sits below the lowest value the controller accepts. For a voltage-type sensor this usually points to a short to ground on the signal wire, a missing reference supply or a sensor pulling the line down internally; with switch-type inputs the contact may read as permanently closed to ground. The circuit fault P2790 and the high-side fault P2792 cover the other failure types of the same signal. No manufacturer documents P2791 publicly, so thresholds and debounce times are unknown; the check is one of the out-of-range tests CARB 13 CCR 1968.2 demands for transmission inputs. Measure supply and signal at the sensor connector before replacing the select actuator. The gearbox typically blocks lane changes and may freeze the current gear.
Possible causes
- Signal wire chafed and shorted to ground high
- Sensor reference voltage missing or shorted medium
- Select direction sensor failed with low output medium
Symptoms
- No change between shift lanes, limited gear choice
- Gearbox holds the current gear or selects neutral
- Transmission warning lamp
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P2791
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.