P272C
Park Pawl Motor Control Circuit
P272C concerns the control circuit of the motor that engages and releases the park pawl. In the shift actuator of the 2022 Mitsubishi Outlander with CVT this is winding B, powered through its own relay B, while winding A is reported under P272A. The detection mirrors that code: with ignition on and the actuator idle, any phase of B reading low without being energised triggers it, and an after-run test with ignition off switches the relays off one at a time and turns the motor a little. Causes named are an open relay B circuit, an open phase line, relay B stuck off, coil B or the shift module. Because the other winding can still drive the actuator, a single fault has no effect on driving; only when both circuits fail are shifts blocked and the car placed in neutral.
Possible causes
- Shift actuator relay B open or stuck off high
- Open phase wire to motor coil B medium
- Faulty motor coil B in the actuator medium
- Electric shift control module fault low
Symptoms
- MIL on, Park still works normally
- Shifting blocked if the other circuit also fails
Inspection / repair
- Difficulty: shop only
- DIY: shop recommended
What Pro shows you for P272C
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.