P26E1
Sensor Power Supply D Circuit High
With P26E1 the fourth sensor supply of the control module reads higher than its regulated value. Deutz assigns it to SPN 3512 with FMI 0, meaning a reading beyond the upper physical limit, rated as most severe. Since the module regulates this output itself, an excessive reading normally comes from outside: a wire of supply D shorted to battery voltage or to another, higher supply, or a sensor feeding voltage back. Raised supply shifts every signal of the sensors connected to it and can damage them, so the module usually reacts strongly. Fewer real-world cases arise than for P26E0, but checking the harness for melted sections near hot or moving parts is the first step. Open circuits on the same output fall under P26DF.
Possible causes
- Supply D wire shorted to battery voltage or a higher supply high
- Faulty sensor feeding voltage back into the supply rail medium
- Regulator for supply D in the control module defective low
Symptoms
- Check engine light
- Implausible readings from several sensors
- Possible derate depending on the sensors involved
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P26E1
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.