Fuel Shutoff Valve B Control Circuit Stuck On
P26B6 reports that shut-off valve B cannot be switched off: the control circuit or the valve remains in the on state after the module removes the command. No manufacturer documents P26B6 publicly. Where valve B is defined, it is a solenoid on the low-pressure side, for example the supply solenoid of the Roush propane rail pressure module (circuit code P2665) or, on GM's CNG Impala, one of two normally closed cut-off valves, the other sitting at the tank. Possible reasons are a control line shorted to power, a welded relay contact or a valve stuck open. Unlike P26B5, the engine usually still starts; the concern is that fuel is no longer sealed off when parked. CARB requires output components to be monitored. Repair soon and use the manual valve if gas is smelled.
Possible causes
- Control line shorted to battery voltage high
- Welded relay contact keeping the valve powered medium
- Valve B stuck open mechanically medium
Symptoms
- Check engine light
- Fuel odour near the engine or regulator after shut-off
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P26B6
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?