P26B4
Fuel Shutoff Valve A Control Circuit Stuck On
P26B4 is the opposite failure to P26B3: shut-off valve A stays open or energised when the module wants it closed. No manufacturer documents P26B4 in public sources. On the Roush propane system for Ford trucks, valve A is the tank solenoid (its open-circuit code is P0005), and GM's 2015 Impala Bi-Fuel uses two normally closed CNG cut-off valves that the ECM opens only in gas mode while the engine cranks or runs. A valve that cannot close defeats that safety function, so fuel may keep flowing into the lines after shut-off. Typical causes are a short to voltage on the control wire, a stuck driver or relay, or a mechanically jammed valve. CARB requires output monitoring. Have it fixed promptly; close the manual tank valve if fuel can be smelled.
Possible causes
- Control wire shorted to battery voltage high
- Supply relay or driver stuck on medium
- Valve A mechanically jammed open medium
Symptoms
- Check engine light
- Fuel odour after shut-off
- Fuel pressure remains in the lines with the engine off
Inspection / repair
- Difficulty: hard
- DIY: shop recommended