P2684
Actuator Supply Voltage C Circuit/Open
Some transmission controllers power groups of solenoids through several internal high-side outputs; supply C is the third of these rails, after A (P0657) and B (P2669). P2684 reports an open load on it. GM's 2023 and 2024 TCM tables tie the code to high-side output 7 and test it while the module powers down: with the output off and a low-side driver on, the load should drag the line low, so a level above 40 % of battery voltage is remembered as an open load and reported after the next start, Type A. Ford's 2024 summary assigns P2684 to high side driver 7 of the TR9070 dual-clutch gearbox, and Ford's 2014 Boss 302S code list carries it as well. Whatever hangs on that rail stops working, so a default gear or limp mode is likely.
Possible causes
- Broken wire or loose terminal between the module output and the supplied solenoids high
- Corroded or unseated transmission connector or internal lead frame medium
- High-side output inside the controller defective low
Symptoms
- Transmission in default gear or limp mode
- MIL on after restart
- Several solenoid circuit codes stored together
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P2684
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 3 affected components(visible in Pro mode)
- 4 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?