P267B
"B" Rocker Arm Actuator Position Sensor Circuit Range/Performance (Bank 2)
P267B concerns the bank 2 feedback of lift actuator B when the signal is electrically sound but the angle it reports does not follow the commanded value, moves too slowly, or contradicts the mechanism's known travel. Faulty learning of the end stops, a slipping sensor mount, wear in the shaft drive or a sticking actuator can all produce this picture. No manufacturer documents P267B publicly. The closest published case is Toyota's bank 1 counterpart P265B on Valvematic engines: bulletin T-SB-0098-19 starts with a learn value reset and an active test of the shaft angle, then replaces the lift controller if the fault returns. CARB expects variable lift monitors to detect missed targets and slow response. Lift on bank 2 is usually frozen.
Possible causes
- End-stop learn values lost or wrong after repair or battery disconnect medium
- Worn or sticking shaft drive of actuator B on bank 2 medium
- Position sensor drifting or loose in its mount medium
- Lift control software needing an update low
Symptoms
- Check engine light on
- Hesitation or reduced power
- Uneven idle when lift is frozen on one bank
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P267B
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 4 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.