P267A
"B" Rocker Arm Actuator Position Sensor Circuit (Bank 2)
Continuously variable lift systems turn a control or eccentric shaft with an electric motor and report the shaft angle back to the engine controller. On V engines each cylinder bank has its own mechanism; Nissan's VVEL on the VQ37VHR V6 and VK50VE V8 is an example of such a two-bank layout. P267A is the unspecific circuit fault of feedback sensor B on bank 2: the signal is unusable, but the controller does not classify it as too low or too high. No manufacturer documents P267A publicly; Toyota's bulletins use the B sensor letter only for its inline Valvematic engines and code P265B. CARB requires electrical checks on every input of a lift system. Expect connector, supply or ground problems first; P267B to P267E name more specific failure patterns.
Possible causes
- Loose, corroded or damaged plug at the bank 2 position sensor high
- Broken or chafed signal, reference or ground wire medium
- Internal fault of position sensor B, bank 2 medium
- Fault in the engine or lift control module input low
Symptoms
- Check engine light on
- Variable lift on bank 2 held at a fixed default
- Reduced power or rough idle
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P267A
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?