P266C
"A" Rocker Arm Actuator Position Sensor Circuit Low (Bank 2)
P266C reports a bank 2 position sensor signal for actuator A that has fallen under its lower plausibility limit. Grounded signal wires, a missing sensor supply or an internal sensor short pull it down; a connector left half unplugged after other work on the harder-to-reach side of the engine is another possible trigger. No manufacturer documents P266C publicly, so there are no published thresholds. Under CARB's comprehensive component rules, such a range check is mandatory for sensors in a lift system. The controller then holds bank 2 at a safe fixed lift. The high-side partner is P266D, the bank 1 equivalent P264C.
Possible causes
- Bank 2 sensor signal shorted to ground high
- Connector not fully seated after other repairs medium
- Missing sensor supply voltage medium
Symptoms
- MIL on
- Bank 2 held at fixed lift
- Less pulling power
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P266C
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.