P2662
"B" Rocker Arm Actuator System Stuck On (Bank 2)
With P2662 the controller concludes that stage B on bank 2 stays switched after it has requested the default mode. Detection depends on the design: a pressure switch that keeps indicating oil pressure, or engine behaviour on that bank that still matches the engaged state. A solenoid that seeps oil when closed, a return path that cannot drain, or locking pins jammed by debris or wear keep the rockers coupled. Because only one bank is affected, the engine may idle unevenly or misfire on that side, especially when cold. No manufacturer documents P2662 publicly; Honda's published stuck-on case for stage B (P2652) refers to bank 1. CARB requires such stuck conditions in valve lift systems to be detected. Opposite fault on this bank: P2661.
Possible causes
- Bank 2 solenoid B seeping oil when closed high
- Blocked drain path keeping oil pressure on the rockers medium
- Locking pins jammed in the coupled position by debris or wear medium
Symptoms
- MIL on
- Uneven idle or misfire on bank 2, worse when cold
Inspection / repair
- Difficulty: medium
- DIY: possible