Powertrain
generic / SAE
P2616
Camshaft A Position Signal Output Circuit High Bank 1
The buffered camshaft A position output is above the expected level on bank 1. Typical causes are a short to battery or an open output stage.
SystemPowertrain
Typegeneric / SAE
GroupP2
Range / number6 / 16
Possible causes
- Output wire shorted to B+ high
- Output buffer open medium
- Connector pins corroded - high contact resistance low
Symptoms
- Check engine light on
- Power loss especially in mid-rpm range
- Possible rough idle or stalling
- Increased fuel consumption
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
- Estimated cost: 120–800 €
- Estimated time: 0.8–3 h
- Component: control module
- Component: signal output buffer
- Component: wiring harness
- MIL / check engine light
Sources
References
sae:J2012