Powertrain
generic / SAE
P260D
PTO Engaged Lamp Control Circuit
The dashboard PTO engaged lamp control circuit is faulty. Driver may not see whether the PTO is currently driving an external accessory.
SystemPowertrain
Typegeneric / SAE
GroupP2
Range / number6 / 0D
Possible causes
- Burnt-out indicator bulb high
- Open or shorted wire between cluster and ECU medium
Inspection / repair
- Difficulty: easy
- DIY: possible
- Estimated cost: 20–150 €
- Estimated time: 0.2–1 h
- Component: pto indicator lamp
- Component: instrument cluster
- Component: wiring harness
- MIL / check engine light
Sources
References
sae:J2012