P255D
PTO Speed Selector Sensor/Switch 2 Circuit High
P255D is stored when PTO speed selector 2 delivers a signal above the permitted maximum. A chafed wire touching a battery-fed circuit, a lost sensor ground, or an upfitter feeding 12 V into an input meant to be switched to ground are the realistic causes. Upfitter manuals show why the last point matters: Ram describes its VSIM preset inputs as switch-to-ground circuits, while GM's 2008–2014 remote set input interprets anything above 3.33 V as a speed request, so mixing up the conventions of different trucks produces readings outside the expected range. No manufacturer documents P255D publicly. P255C is the low-side code; P254D covers selector 1. The second preset may be unavailable or the PTO is shut off.
Possible causes
- Selector 2 wire chafed against a battery-fed circuit high
- Upfitter applies 12 V to a ground-switched input medium
- Lost ground or return line of selector 2 low
Symptoms
- Second preset unavailable
- PTO switched off by the controller
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P255D
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.