P24DC
Reductant Purge Control Valve B Performance
P24DC judges purge valve B by its effect, not by its wiring: once the controller switches the valve to purge, the pressure in the DEF line it serves should fall noticeably, and here it did not. No manufacturer documents P24DC publicly. On the 6.6 L Duramax, GM tests valve A under P20A1: if, when the pressure reduction phase ends, the pump pressure is less than 50 kPa below its starting value, the fault is set, Type A, sampled every 100 ms. Pico's description of the Denoxtronic 2.2 explains why: in purge mode the reversing valve makes the pump pull fluid out of the line, so a vacuum should build. A valve that does not shift, a blocked return or a misreading pressure sensor all end here. Electrical faults of valve B are P24DB, P24DD and P24DE.
Possible causes
- Valve B mechanically stuck by crystallised DEF high
- Blocked return path or filter in the supply module medium
- DEF pressure sensor reading incorrectly low
Symptoms
- Malfunction indicator lamp on
- Frozen DEF line or dosing fault after cold nights
Inspection / repair
- Difficulty: medium
- DIY: shop recommended