Reductant Heater A Sense Circuit
Besides the control output, many DEF heaters have a sense line on which the controller reads back the voltage actually reaching the element. P24D2 marks a general fault on this sense circuit for heater A, such as an open lead or a reading that makes no sense at all, as opposed to the voltage being merely too low (P248A) or too high (P248B). GM and Ford call heater A the tank heater. No manufacturer documents P24D2 publicly. GM's 2016 to 2018 diesel tables show the related sense test: system voltage minus heater supply must not exceed 3 V while heating is commanded, judged over 10 of 12 samples at 500 ms. CARB requires SCR heaters and their circuits to be monitored. If the sense signal is lost, the controller cannot confirm thawing, so dosing in frost may stay off.
Possible causes
- Broken or disconnected sense wire to heater A high
- DEF creep or water corroding the heater connector medium
- Faulty measuring input in the SCR or engine control module low
Symptoms
- Malfunction indicator lamp on
- DEF warnings in cold weather, dosing delayed after a cold start
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P24D2
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.