EVAP System Leak Detection Pump Pressure Sensor Circuit High
P24BB is stored when the leak check module's pressure signal climbs above the top of its usable range. GM uses 4.85 V, about 97 % of the reference or roughly 120 kPa, again with 640 of 800 samples and Type B; the limit appears unchanged from the 2018 Volt up to GM's 2025 table 25OBDG03A for conventional ELCP systems. Mitsubishi's 2023 Outlander PHEV flags the code above 4.9 V lasting 2 s. Subaru lists P24BB with P24BA and P24B9 as faults to clear first when P2404 appears. A reading pinned high usually comes from an open ground, a signal wire touching a voltage source or an internal sensor fault, rarely from real pressure. P24BA covers the low side; P24B9 a signal that stays in range but disagrees with barometric pressure.
Possible causes
- Open sensor ground or signal wire, letting the input float high high
- Signal wire shorted to the 5 V reference or battery voltage medium
- Pressure sensor inside the leak check module failed medium
Symptoms
- Malfunction indicator lamp on
- EVAP leak test not run, readiness incomplete
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P24BB
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?