P24B8
EVAP System Leak Detection Pump Pressure Sensor Circuit
P24B8 is the general circuit fault of the pressure sensor that sits inside an evaporative leak check module together with the pump and the switching valve. The sensor gets a 5 V reference from the engine computer and reports canister-side pressure during the engine-off leak test. No manufacturer documents P24B8 publicly; GM, Mitsubishi and Subaru use the more specific P24B9 to P24BB for this sensor. CARB requires such EVAP input components to be checked for circuit faults and implausible values. With this fault present, the leak test cannot be trusted and will not complete, so the EVAP readiness flag stays open. Typical findings are a broken reference or ground wire, a corroded module plug or a failed module.
Possible causes
- Open or shorted 5 V reference, ground or signal wire to the leak check module high
- Corroded or loose connector at the leak check module near the canister medium
- Pressure sensor inside the leak check module failed medium
- Engine control module does not supply the sensor reference low
Symptoms
- Malfunction indicator lamp on
- EVAP readiness monitor does not complete
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P24B8
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.