P24AB
EGR Cooler Coolant Pump Stuck On
P24AB is set when the EGR cooler coolant pump keeps running although the controller has switched it off, seen for instance in continued speed feedback or current draw. Causes include a driver stage or relay that stays closed, a short that bypasses the switching side, or pump electronics that ignore the command. For the driver this is less urgent than a pump that will not run, but a constantly running pump drains the battery after shut-off and can slow engine warm-up. Public documentation of this check by a carmaker was not found; it follows from CARB's demand that switched outputs be verified in operation. P24A8 covers the opposite failure, P24A9 a short to ground that may keep the pump running.
Possible causes
- Relay or controller output stage stuck closed high
- Short in the harness bypassing the switched side medium
- Pump electronics no longer responding to the command low
Symptoms
- Pump audible after engine shut-off
- Battery drained after standing
- Malfunction indicator lamp on
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P24AB
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?