P24A7
EGR Cooler Coolant Pump Control Circuit/Open
Some diesel engines feed the EGR cooler with an electric auxiliary coolant pump so the cooler gets flow at low engine speed or after shut-off, independent of the main pump. P24A7 means the engine controller sees an open or otherwise faulty control line to this pump, typically when the driver stage detects no load while switching. No manufacturer documents this code publicly with thresholds, and no NHTSA bulletin index entry names it; the text relies on CARB's comprehensive component rules for outputs and on supplier information on EGR coolers in the coolant circuit. Check connector, wiring and pump fuse first. P24A9 and P24AA split the same circuit into shorts to ground and to supply. Without flow the cooler can overheat, so EGR may be reduced.
Possible causes
- Loose, corroded or unplugged pump connector high
- Broken control wire in the harness medium
- Open winding or electronics in the pump medium
Symptoms
- Malfunction indicator lamp on
- EGR may be reduced, NOx output rises
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P24A7
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?