P24A6
EGR Cooler Bypass Control Stuck/Open (Bank 2)
P24A6 is reserved for a mechanically stuck cooler bypass on bank 2. No manufacturer documents it publicly; the Ford and GM diesel summaries that describe the stuck test all apply it to a single bank and use P24A5. Their methods show how a second bank would be checked: either the measured flap position is compared with where it should rest, or the flap is switched and the gas temperature after the cooler must respond, as CARB's EGR cooler requirements expect. On a twin-cooler V engine a stuck bank 2 flap leaves that side either always bypassing, raising NOx, or always cooling, which slows warm-up and adds soot. Carbon build-up and a failing actuator are the likely reasons. Electrical faults on this bank are P248E, P2490 and P2491; the drift check is P248F.
Possible causes
- Bank 2 flap seized by deposits high
- Bank 2 actuator or linkage failed medium
- Missing vacuum on a pneumatically switched bypass low
Symptoms
- Check engine light on
- Uneven exhaust temperatures between the two banks
Inspection / repair
- Difficulty: hard
- DIY: shop recommended
What Pro shows you for P24A6
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.