P2498
EGR Cooler Bypass Position Sensor Range/Performance (Bank 2)
With P2498 the bank 2 bypass position signal is electrically valid but not believable, for example because it does not change when the flap is commanded, settles at an unexpected value or no longer matches the end stops learned earlier. There is no public manufacturer description for this bank 2 code. The closest documented case is bank 1: GM's 2015 LML Duramax showed P2493 together with other bypass sensor codes, and GM's answer was a complete new bypass valve, because sensor and valve form one unit. On a twin-cooler engine the same reasoning applies to the second bank, so a sensor fault and a mechanically binding flap must be told apart with live data before parts are ordered. The bank 1 version is P2493; the actuator side of bank 2 is P248F.
Possible causes
- Worn bank 2 bypass valve with built-in sensor high
- Flap binding so the sensor reads a position other than commanded medium
- End-stop learn values invalid after a repair low
Symptoms
- Check engine light on
- Measured and commanded bypass position differ on bank 2
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P2498
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.