P2494
EGR Cooler Bypass Position Sensor Circuit Low (Bank 1)
P2494 is set when the raw voltage of the bank 1 bypass position sensor drops toward zero. GM documents it for the Duramax diesel: in the 2017 tables the signal must be below 1 % of the 5 V reference in 200 of 250 samples, checked every 6.25 ms once cranking is over and the powertrain relay supplies more than 11 V. The 2018 tables keep the test and the Type B rating, so the lamp comes on after two trips. GM groups P2494 with P2495 and P24C4 in one sensor fault bundle, which makes the bypass control fall back to a default. A signal near zero points to a short to ground, a missing 5 V supply or a broken signal wire pulled down inside the controller. High voltage is P2495; on bank 2 the low case is P2499.
Possible causes
- Signal wire shorted to ground high
- Open 5 V reference wire to the sensor medium
- Internal sensor fault in the bypass valve medium
Symptoms
- Check engine light after two trips
- Bypass control falls back to a default position
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P2494
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.