P2491
EGR Cooler Bypass Control Circuit High (Bank 2)
P2491 reports excess voltage or excess current in the drive circuit feeding the bypass actuator on bank 2, the classic sign of a short to supply or of a winding whose resistance has collapsed. It is the bank 2 sibling of P245D, and no maker publishes its own description of it. GM's 2017 tables show how a bank 1 DC-motor flap is protected: if H-bridge current climbs past 8 A in 160 of 200 samples, the output is flagged and the code is rated Type B. Many controllers switch off the affected driver to protect it, so the flap falls back to its spring-loaded rest position. A blown fuse feeding the actuator or a damaged controller output can accompany the code. Open circuit is P248E, ground short P2490.
Possible causes
- Control wire touching a battery or ignition feed high
- Actuator winding with too low resistance or seized motor medium
- Controller software reporting a false actuator fault low
Symptoms
- Check engine light on
- Bypass flap on bank 2 rests in its default position
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P2491
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.