P248E
EGR Cooler Bypass Control Circuit/Open (Bank 2)
P248E is the bank 2 counterpart of P245A: the engine controller sees no proper load on the output that drives the EGR cooler bypass of the second cylinder bank, most often because the circuit is open. Only engines with a separate EGR path per bank can set it, which in practice means V engines with two coolers. No manufacturer documents this code publicly; the published diesel tables we checked only list bank 1. For comparison, GM's 2017 Duramax tables flag the bank 1 DC-motor flap when the load resistance with the H-bridge switched off exceeds 200 kOhm, rated Type B. CARB requires such actuators to be checked as comprehensive components. With the flap unpowered, warm-up or cooling of the recirculated gas is no longer controlled on that bank.
Possible causes
- Unplugged connector or broken wire at the bank 2 bypass actuator high
- Open motor or solenoid winding in the bank 2 actuator medium
- Faulty output stage in the engine control module low
Symptoms
- Check engine light on
- Longer warm-up or higher NOx on one bank because the bypass stays put
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P248E
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.