P2489
Exhaust Gas Temperature Sensor Circuit Intermittent/Erratic (Bank 2 Sensor 5)
P2489 points to an unsteady signal from the fifth exhaust probe on bank 2: the value stays within its electrical limits but jumps or drops out briefly. This code is not documented by any manufacturer, as no public layout carries five probes per bank on a twin-bank engine. For the bank 1 position GM shows the method under P2484: samples every 100 ms are compared, and in 2025 a step above 100 °C in 12 of 25 samples, valid only between 140 and 1070 °C, sets a Type B fault. CARB requires monitoring of inputs for erratic behaviour where it affects emissions. Such faults usually come from loose terminals or a harness that touches hot parts, so a careful check of routing and clips pays off.
Possible causes
- Loose terminal in the connector high
- Harness touching hot exhaust parts medium
- Internal crack in the probe low
Symptoms
- Warning lamp coming and going
- Jumping value in live data
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P2489
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.