Powertrain
generic / SAE
P241D
SCR Inducement Forced Engine Shutdown
The SCR inducement strategy (mandatory regulatory measure to enforce AdBlue refilling and emissions compliance) has reached the final stage and shut down the engine. Refill AdBlue and clear inducement fault to restart.
SystemPowertrain
Typegeneric / SAE
GroupP2
Range / number4 / 1D
Possible causes
- AdBlue tank empty or out of compliance high
Symptoms
- Check engine light or NOx warning on
- AdBlue/DEF level or quality warning
- Possible no-start countdown after ignore period
- Failed emissions inspection (NOx)
Inspection / repair
- Difficulty: easy
- DIY: possible
- Estimated cost: 20–200 €
- Estimated time: 0.2–0.8 h
- Component: scr system
- Component: reductant tank
- MIL / check engine light
- emissions-relevant
Sources
References
sae:J2012