P2402
EVAP System Leak Detection Pump Control Circuit High
P2402 points to the opposite fault of P2401: the pump control line sits at supply voltage or the pump draws too much current. GM's Volt tables call it a short to power detected while the driver is on; when it is active the ECM runs an intrusive check, running the pump for 15 s on command, with a Type B code after 20 failed samples out of 25. In VW's Golf data book of 2014 the limit is a pump current above 3.0 A or, on other engines, the voltage across the pump's current-measuring resistor (about 1.8-4.0 V). Acura recalled 2021-22 TLX Type S models (B22-007) because faulty PGM-FI software could keep the MIL on and P2402 stored after an ELCM circuit repair; Audi and Land Rover also publish P2402 cases. Driving is unaffected, but the evaporative leak check is skipped.
Possible causes
- Leak detection pump motor seized or drawing excessive current high
- Control wire shorted to a battery-voltage feed medium
- Control module software that does not clear the fault after repair (Acura TLX Type S recall) low
Symptoms
- Check engine light that may persist after repair until software is updated
- EVAP readiness incomplete, inspection may fail
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P2402
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.