P23DA
Cylinder 3 Fuel Heater Control Circuit High
P23DA tells that the control side of the cylinder 3 heater sits at a high level. The likely pictures are a control wire touching a positive feed, so voltage stays on the line when the channel is off, or an output stage that has failed conducting, so heater 3 runs without command. The second case is the costly one: Bosch rates one heat circuit at about 260 W at 12 V, which is more than 20 A, and a heater that keeps running after the engine is shut off will drain the battery within a few hours. A heater 3 that is still warm long after switch-off, or an unexplained flat battery, fits this code. No manufacturer publishes P23DA; CARB requires the circuit to be monitored. Low fault: P23DB, open: P23D9, cylinder 2 counterpart: P23D6.
Possible causes
- Channel 3 output stage failed conducting high
- Cylinder 3 control wire shorted to a positive feed medium
- Heater supply relay contacts welded low
Symptoms
- Flat battery after the car has stood for some hours
- Heater at cylinder 3 warm long after switch-off
- Engine warning lamp, depending on manufacturer
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P23DA
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.