P23D7
Cylinder 2 Fuel Heater Control Circuit Low
For P23D7 the module reads the cylinder 2 heater control line as low, which on these power circuits nearly always means a path to ground: a chafed wire, a heater element shorted to its body, or fuel or water bridging the connector pins. The short draws more than the channel is meant to carry, so the heater unit protects itself; Bosch mentions reverse-voltage and internal overtemperature protection as well as short detection per circuit. In practice the heater on cylinder 2 is switched off and that cylinder starts cold while cylinders 1, 3 and 4 still get warm fuel; a blown heater fuse is possible. No manufacturer documents P23D7 publicly; CARB demands circuit checks on this output. High and open on cylinder 2: P23D6, P23D5; cylinder 1 equivalent: P23D3.
Possible causes
- Cylinder 2 heater wire chafed through to ground high
- Heating element at cylinder 2 shorted to its housing medium
- Fuel or water bridging pins in the cylinder 2 heater plug medium
Symptoms
- Rough cold start on one cylinder
- Fuel heater fuse blown
- Engine warning lamp, depending on manufacturer
Inspection / repair
- Difficulty: medium
- DIY: shop recommended
What Pro shows you for P23D7
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.