P23B9
NOx Sensor Heater Sense Circuit High (Bank 1 Sensor 3)
P23B9 is the counterpart of P23B8: the temperature feedback wire of NOx sensor 3 on bank 1 carries a voltage that only a short to battery or to another live wire can explain. The sensor then cannot report a trustworthy heater temperature, so it withholds its NOx output. GM applies this check to the post-second-catalyst sensor in 25OBDG04B (2025) under the same frame as the ground short: powertrain relay above 11 V, sensor supply above 9.90 V, dew point reached, and half of 160 samples (80) must fail before this Type B code is stored. A harness overheated near the exhaust, where insulation melts between neighbouring wires, is a classic trigger; the same 21-NA-149 bulletin for the 3.0L LM2 includes P23B9. P2211 and P22A9 cover sensors 1 and 2.
Possible causes
- Sense wire shorted to the heater supply or another battery-fed wire high
- Harness insulation melted by contact with hot exhaust parts medium
- Internal fault in the sensor or its control unit medium
Symptoms
- Check engine light after two trips
- No NOx reading from sensor 3
- Possibly a blown fuse in the sensor supply
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P23B9
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 2 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.