P23B7
NOx Sensor Heater Control Circuit Range/Performance (Bank 1 Sensor 3)
P23B7 is set when the heater drive of NOx sensor 3 on bank 1 looks electrically sound but does not behave as the control strategy expects, for instance a heater duty cycle far from what the element should need to reach operating temperature. No manufacturer documents P23B7 publicly; GM's 2025 table covers sensor 3 only with the plain heater circuit codes P23B1-P23B3 and the resistance check P23B5. Ford's 2023 diesel summary shows how the front-sensor counterpart P220E is judged: apart from open and shorted heaters a heater whose duty cycle misses the expected figure by over 20 percent is also treated as faulty. CARB requires sensor heater performance to stay within the supplier's limits. If the element never gets hot enough, sensor 3 stays inactive; P220F is the sensor 2 version.
Possible causes
- Aged heater element that needs far more or less power than expected high
- High resistance in heater supply or ground contacts medium
- Sensor supply voltage at the lower limit, so the heater cannot keep up low
Symptoms
- Check engine light on
- Sensor 3 takes long to become ready or drops out of its active state
- SCR efficiency monitor not completing
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P23B7
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 1 affected component(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.