P22A9
NOx Sensor Heater Sense Circuit High (Bank 1 Sensor 2)
P22A9 is the high-side twin of P22A8: the heater sense line of the rear NOx sensor on bank 1 has a short to supply voltage. The module then reads an element resistance that is far off and loses its temperature feedback, so it cannot hold the probe at working temperature. GM's 3.0L LZ0 looks for a battery short at the HTemp pin once dew point is reached and supply exceeds 9.9 V, 80 failures in 160 samples, Type B after two trips; the 2017 small diesels need 20 failures in 40 samples. In both cases the Continental sensor itself confirms an electrical fault before reporting it. No manufacturer bulletin mentions P22A9. A short often sits where the probe lead runs close to other powered wiring or where a connector has taken in water. P22A6 is the open circuit, P22A8 the ground short, P2211 the front sensor.
Possible causes
- Heater sense conductor shorted to supply inside the probe high
- Probe lead touching another powered conductor medium
- Water bridging pins in the probe connector low
Symptoms
- Malfunction indicator lamp on after two trips
- Outlet NOx sensor not ready
- SCR warning on the display
Inspection / repair
- Difficulty: medium
- DIY: possible
What Pro shows you for P22A9
Before you go to the garage: roughly what the repair costs, how long it takes and which components are involved.
- Repair cost (estimate)(visible in Pro mode)
- Labour time(visible in Pro mode)
- 2 affected components(visible in Pro mode)
- 3 warnings for driving and inspection(visible in Pro mode)
See repair cost, labour time and components?
One key opens all tools by Fabian Brose.